The Most Critical Design Criteria for
Radiation Shielding Windows
Shielding
- Wall Type (e.g. concrete, steel, lead)
- Wall Density (in g/cc or lbs./ft.3)
- Thickness (in inches or mm)
And
- Isotope Source (e.g. Co60)
- Maximum Dose Rate (R/h) and Energy Level (MeV)
- Distribution (point or plane)
- Geometry/Position Of Source
- Duration (Load/Time Factor)
- Cold Side Dose Permitted (e.g. 0.25 m R/h)
- Lifetime Dose (10xR), Design Life (yrs)
Viewing
- Window Size; Clear view size and largest plate size
- Cell Layout With Respect To Window Location
- Objects To Be Viewed With Regards To Their Distance
& Location From Window Centerline
- Viewing Angles; Normal and Extreme
- Light Transmittance
Back to Topic List